<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>DSpace Community: All collections of E.E.E</title>
    <link>http://103.99.128.19:8080/xmlui/handle/123456789/27</link>
    <description>All collections of E.E.E</description>
    <pubDate>Tue, 17 Nov 2026 03:15:06 GMT</pubDate>
    <dc:date>2026-11-17T03:15:06Z</dc:date>
    <item>
      <title>Circularly Polarized Microstrip Patch Array Antenna for Satellite Applications: An Approach Using Simple Feed Network</title>
      <link>http://103.99.128.19:8080/xmlui/handle/123456789/608</link>
      <description>Title: Circularly Polarized Microstrip Patch Array Antenna for Satellite Applications: An Approach Using Simple Feed Network
Authors: Rahman, Md Mahfuzur; ID:, 19MEE003P
Abstract: Microstrip antennas, among various types of antennas, offer considerable ad&#xD;
vantages over traditional microwave antennas and are consequently utilized in&#xD;
numerous practical applications. Circularly polarized (CP) microstrip patch ar&#xD;
ray antennas offer numerous benefits, such as reduced sensitivity to polarization&#xD;
orientation, the capability to counteract the ionosphere’s Faraday rotation effect,&#xD;
enhanced resistance to interference, and improved long-distance transmission.&#xD;
Consequently, they play a crucial role in radar systems, satellite communica&#xD;
tions, GPS, and various other applications. Furthermore, a reconfigurable an&#xD;
tenna functions as a multifunctional apparatus, yielding a more compact and&#xD;
efficient design while also reducing expenses. Polarization reconfigurable anten&#xD;
nas can switch between various polarization modes, including LP, LHCP, and&#xD;
RHCP. This thesis presents the construction of a 2×2 dual-sense circularly po&#xD;
larized octagonal-shaped microstrip array antenna, followed by the integration&#xD;
of pin diodes to achieve reconfigurable circular polarization for the Ku-band fre&#xD;
quency suitable for satellite communication. Both antennas have a single in&#xD;
put feed and utilize dual-sided microwave integrated circuit (MIC) technology&#xD;
to enhance design flexibility and simplify the bias control circuit, resulting in&#xD;
a straightforward feeding circuit for the antenna. Each segment of the array is&#xD;
stimulated orthogonally. The switching mechanism is regulated by a single-pole&#xD;
double-throw (SPDT) switch composed of two PIN diodes integrated within a&#xD;
λ/2 delay line. The simulated outcomes indicate that the antenna may alternate&#xD;
between RHCP and LHCP, showcasing proficient circular polarization perfor&#xD;
mance. The simulated findings demonstrate excellent circular polarization (CP)&#xD;
performance, with a relative power level difference of 30 dB and an ARBW of&#xD;
400 MHz. The array demonstrates effective impedance matching, featuring an&#xD;
impedance bandwidth of 1600 MHz. The gain, directivity, and efficiency find&#xD;
ings indicate that the antenna effectively transmits a highly focused beam in the&#xD;
broadside direction.
Description: A Master of Science (M.Sc) Thesis in Electrical and Electronic Engineering (EEE) Department at Chittagong University of Engineering and Technology (CUET).</description>
      <pubDate>Mon, 28 Jul 2025 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://103.99.128.19:8080/xmlui/handle/123456789/608</guid>
      <dc:date>2025-07-28T00:00:00Z</dc:date>
    </item>
    <item>
      <title>Investigation of Dust-Related Energy Losses in Rooftop Solar  PV Systems: A Case Study in Chittagong Town</title>
      <link>http://103.99.128.19:8080/xmlui/handle/123456789/601</link>
      <description>Title: Investigation of Dust-Related Energy Losses in Rooftop Solar  PV Systems: A Case Study in Chittagong Town
Authors: Roy, Rashmi; ID:, 21MEE016P
Abstract: The accumulation of dust on rooftop solar photovoltaic (PV) systems is a critical factor &#xD;
that reduces the overall energy output, particularly where the dust accumulation rate is higher. &#xD;
This thesis investigates the impact of dust accumulation on the efficiency of rooftop solar &#xD;
photovoltaic (PV) systems in Chittagong City in four key locations which represent different &#xD;
types of environmental conditions throughout the city, Likes- CUET is located in a semi-urban &#xD;
area, AECC is located in an industrial area, BPDB is located in a commercial area and NMI is &#xD;
located in an EPZ area respectively, focusing on how dust reduces solar light transmittance and, &#xD;
consequently, energy output and analyzes the elemental composition of the dust contributing to &#xD;
it. Dust samples were collected from these four locations, and analyzed using Scanning Electron &#xD;
Microscopy (SEM), Energy Dispersive X-ray (EDX) spectroscopy, and UV transmittance tests. &#xD;
And also set up two 550wp solar panels on the rooftop of the CUET’s professor building block &#xD;
to investigate the real scenario of degradation of efficiency in a regular clean panel and unclean &#xD;
panel. &#xD;
The SEM and EDX analyses revealed significant variations in dust composition: CUET &#xD;
samples showed high carbon content (13.09% to 62.71%) with high light absorbing properties &#xD;
which originate from vehicular emissions, burning fossil fuel and industrial activities, while NMI &#xD;
samples had high oxygen that often bound with other elements in the form of oxides (e.g., silica &#xD;
as silicon dioxide, calcium oxide, iron oxide, aluminium oxide) (41.74% to 44.92%). The AECC &#xD;
location showed the highest silicon (commonly present as silica (SiO₂) in sand) content (up to &#xD;
38%), which correlated with a notable decline in transmittance. BPDB locations also varied, with &#xD;
silicon, iron, and calcium being prominent in certain locations. These elements significantly &#xD;
affected solar transmittance, reducing the panels' energy output. The study found that dust &#xD;
accumulation can reduce solar light transmittance by 10% to 42%, depending on the dust &#xD;
composition, location and also seasonal variation — in the dry season solar transmittance is lower &#xD;
and in the wet season is higher. Energy output data from two 550 Wp solar PV systems at the &#xD;
CUET location showed the highest efficiency drop of 21.28% in April due to dust accumulation.  &#xD;
The findings highlight the necessity for regular cleaning and maintenance of solar panels, &#xD;
especially in environments like Chittagong where dust accumulation is prominent. Based on the &#xD;
analysis, cleaning intervals and methods tailored to each location’s dust composition are &#xD;
recommended to optimize energy output. This research provides practical insights into improving &#xD;
the performance of rooftop PV systems, contributing to enhanced renewable energy efficiency &#xD;
in urban settings.
Description: A Master of Science (M.Sc) Thesis in Electrical and Electronic Engineering (EEE) Department at Chittagong University of Engineering and Technology (CUET).</description>
      <pubDate>Sun, 19 Jan 2025 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://103.99.128.19:8080/xmlui/handle/123456789/601</guid>
      <dc:date>2025-01-19T00:00:00Z</dc:date>
    </item>
    <item>
      <title>EEG Signal Classification between Audio and  Visual Stimulation and Multi-level Stress Detection</title>
      <link>http://103.99.128.19:8080/xmlui/handle/123456789/586</link>
      <description>Title: EEG Signal Classification between Audio and  Visual Stimulation and Multi-level Stress Detection
Authors: Troyee, Trishita Ghosh; ID:, 21MEE005F
Abstract: Stress in the mind and body is a reaction to perceived difficulties or dangers. It &#xD;
can have significant impacts on mental and physical health, affecting cognitive &#xD;
abilities, emotional stability, and physical well-being. To control stress and avoid &#xD;
its long-term impacts, it is essential to comprehend these effects. Mental stress can &#xD;
be detected in many ways and Electroencephalogram (EEG) is one of them. EEG &#xD;
is the graphical representation of Brain's electrical activity. Regular mental stress &#xD;
gives rise to many mental disorders and it may cause various physiological and &#xD;
psychological diseases. As a result, early-stage detection of stress is very &#xD;
important. In this research, brain activity was recorded through EEG headset &#xD;
during inducing different levels of stress from audio-visual stimulus. To better &#xD;
evaluate visual and auditory stress, an automated system is designed to &#xD;
differentiate among various audio and visual evoked potentials. This may further &#xD;
help for designing different assistive devices for the people having visual and &#xD;
hearing disability. Again, many researchers worked on different level of stress &#xD;
detection, but four level stress detection is still unchecked. In this thesis, mental &#xD;
arithmetic tasks were used as both audio and visual stimuli. Here, a framework &#xD;
was proposed to classify different levels of stress in response to audio and visual &#xD;
stimuli and classification was done between these two stimuli by analyzing EEG &#xD;
signals. A proper pre-processing pipeline selection is essential to the effectiveness &#xD;
of EEG-based mental stress detection systems, as noisy EEG data are unlikely to &#xD;
produce improved findings. An ideal EEG pre-processing pipeline was suggested &#xD;
in this work and compared it to the conventional approach now in use. Using the &#xD;
two pre-processing pipelines, raw EEG data was pre-processed which was &#xD;
collected at lab environment. By extracting robust features from the denoised &#xD;
audio and visual data, binary and multi-level stress were classified. Four machine &#xD;
learning (ML) classification models were used for this purpose. On top of that, the &#xD;
audio and visual stimuli was classified with highest 98.37% accuracy using SVM. &#xD;
When the suggested pipeline for pre-processing EEG data was put into practice, &#xD;
a noticeable increase was found in classification accuracy over the traditional &#xD;
approach.  With SVM, the best accuracy of 97.14%, 89.01%, 89.59% were achieved &#xD;
for two, three and four level stress detection using visual stimulation. By contrast, &#xD;
the conventional pipeline produced results of 85%, 77.67% and 66.6%. Again, for &#xD;
auditory stimulation, the highest accuracy of 94.51%, 87.7% and 82.63% was found &#xD;
for two, three and four level stress detection using SVM. On the other hand, the &#xD;
traditional pipeline produced results of 90%, 77.46% and 71.69% respectively.
Description: A Master of Science (M.Sc)  Thesis in Electrical and Electronic Engineering (EEE) Department at Chittagong University of Engineering and Technology (CUET).</description>
      <pubDate>Thu, 22 May 2025 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://103.99.128.19:8080/xmlui/handle/123456789/586</guid>
      <dc:date>2025-05-22T00:00:00Z</dc:date>
    </item>
    <item>
      <title>Techno-Economic Analysis and Design Optimization of Concentrated Solar Power Plants for Sustainable Energy Development in Bangladesh</title>
      <link>http://103.99.128.19:8080/xmlui/handle/123456789/585</link>
      <description>Title: Techno-Economic Analysis and Design Optimization of Concentrated Solar Power Plants for Sustainable Energy Development in Bangladesh
Authors: BHUIYAN, A.B.M. NOUSHAD; ID:, 21MEE025P
Abstract: This study assesses the feasibility of Concentrated Solar Power (CSP) in &#xD;
Bangladesh, evaluating four CSP technologies—Solar Tower (ST), Solar Dish &#xD;
(SD), Parabolic Trough Collector (PTC), and Linear Fresnel Reflector (LFR)—&#xD;
across the three highest Direct Normal Irradiance (DNI) regions: Cox’s Bazar, &#xD;
Bandarban, and Chapai Nawabganj. Key performance indicators, including &#xD;
capacity factor, annual energy generation, Levelized Cost of Electricity (LCOE), &#xD;
and Net Present Value (NPV), were analyzed. Among the technologies, PTC &#xD;
showed the best performance, with a 67.5% capacity factor, 889.26 GWh energy &#xD;
generation, and the lowest LCOE (8.98 ¢/kWh) in Chapai Nawabganj. ST had the &#xD;
highest energy yield (472.09 GWh) in Cox’s Bazar with a competitive LCOE (7.49 &#xD;
¢/kWh). LFR demonstrated strong economic feasibility, achieving an NPV of &#xD;
$382.24 million and a 51.9% capacity factor. SD, while less efficient, was suitable &#xD;
for decentralized applications. A comparative study was conducted against &#xD;
existing CSP projects, including Noor II and Noor III (Morocco) and Dhursar &#xD;
(India), revealing that the designed plants offer higher capacity factors and lower &#xD;
LCOE relative to global benchmarks.  The study utilized System Advisor Model &#xD;
(SAM) for performance optimization, considering solar field design and thermal &#xD;
storage integration. Key challenges include high capital costs and land &#xD;
constraints. Recommendations include hybrid CSP-PV systems and optimized &#xD;
heliostat layouts to enhance feasibility. The findings provide valuable insights for &#xD;
policymakers and investors, laying the groundwork for future CSP development &#xD;
in Bangladesh’s transition toward sustainable energy.
Description: A Master of Science (M.Sc) Thesis in Electrical and Electronic Engineering (EEE) Department at Chittagong University of Engineering and Technology (CUET).</description>
      <pubDate>Mon, 12 May 2025 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://103.99.128.19:8080/xmlui/handle/123456789/585</guid>
      <dc:date>2025-05-12T00:00:00Z</dc:date>
    </item>
  </channel>
</rss>

