Please use this identifier to cite or link to this item: http://103.99.128.19:8080/xmlui/handle/123456789/156
Title: ENHANCEMENT OF HEAT TRANSFER OF WATER FOR TURBULENT FLOW THROUGH TUBE USING U-CUT TWISTED TAPE INSERTS
Authors: Razzaq, Moham Ed
Hossain, M.A.M
Ahamed, J.U.
Keywords: Heat Transfer Enhancement, Insert
Issue Date: 2016
Publisher: Department of Mechanical Engineering, Chittagong University of Engineering and Technology
Series/Report no.: 10;51-56
Abstract: In this experiment tube side heat transfer coefficient, pressure drop, friction co-efficient and percentage of increase in those parameters for water using U-cut twisted tape inserts into the tube were measured. The test section consists of a circular tube made of copper having 26.6 mm inside diameter, 30 mm outside diameter and 900 mm in effective length. A stainless steel U-cut twisted tape insert of 5.29 twist ratio and 0.4 mm in thickness was inserted into the smooth tube. The U-cut had 8 mm depth and 8mm width. In this investigation, the test section was electrically heated. Five K-type thermocouples were used in the test section for measuring the wall temperature. The heat flux was found in the range of 18.33~28 kW/m2 for smooth tube whereas 32.07~47.24.00 kW/m2 for tube with insert for Reynolds number range of 10153~19217. At comparable Reynolds number, Nusselt number in the tube with U-cut twisted tape insert was enhanced by 2.76 to 3.24 times with compared to smooth tube and friction factor in the tube with U-cut twisted tape insert was also increased by 1.6 times with compared to plain tube.
URI: http://103.99.128.10:8080/xmlui/handle/123456789/156
ISSN: 1990-5491
Appears in Collections:Journals in M.E.

Files in This Item:
File Description SizeFormat 
MERJ-10.pdf650.72 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.