Please use this identifier to cite or link to this item: http://103.99.128.19:8080/xmlui/handle/123456789/626
Title: INNOVATIVE ELECTROCHEMICAL SENSOR DEVELOPMENT BY USING DISPOSABLE ELECTRODES FOR ANTIBIOTIC CONCENTRATION MEASUREMENT ACROSS DIVERSE SOURCES
Authors: Akter, Tahmina
ID:, 21MSCHEM002F
Keywords: Electrochemical Sensor
Ciprofloxacin Detection
Gold Nanoparticles (AuNPs)
Chitosan-Modified Electrode
Machine Learning
Differential Pulse Voltammetry (DPV)
Issue Date: 23-Sep-2025
Publisher: CUET
Series/Report no.: ;Tmail-18
Abstract: The prompt detection of trace amounts of antibiotics is crucial for environmental surveillance and the entire ecosystem. An electrochemical sensor has been designed to precisely detect the concentration of ciprofloxacin (CIP) utilizing gold nanoparticles coated with chitosan on a glassy carbon electrode (AuNPs/CHI/GCE). The influence of four key electrochemical parameters, viz., scan rate, pH, temperature, and electrode potential, on the satisfactory detection of CIP was also studied. The accumulated analysis generated one output parameter, which was current intensity, resulting in 2319 data points. This dataset was then used in machine learning models to predict the maximum cathodic current for CIP detection. The best model and its optimal se ings of parameters were determined after comparing ten different ML models: AdaBoost, Bagging, CatBoost, Decision Tree, Extra Trees, Gradient Boosting, HistGradientBoosting, LightGBM, RandomForest, and XGBoost, the performance of the models has been evaluated by metrics Coefficient of Determination (R²), Mean Square Error (MSE), Root Mean Square Error (RMSE), Mean Absolute Error (MAE) and Median Absolute Error (MedAE). It was concluded that CatBoost is the best model both on cumulative performance and final metrics results. These include an R² score of 0.9985, MSE of 1.468, RMSE of 1.225, MAE of 0.672, and MedAE of 0.375. Under optimal conditions, the cathodic current for CIP detection by the CB Model was approximately 128.51 µA, with a potential of 0.47 V, scanning rate of 98 mV/sec, temperature of 310C, and pH of the reaction medium at 6.75. These parameters were further used in constructing a calibration curve using differential pulse voltammetry (DPV), accurately determining the presence of CIP in known and unknown samples. The LOD, LOQ, and the specific sensitivity of the developed sensor (AuNPs/CHI/GCE) were 0.049, 0.232 µM, and 786.72 µA µM−1 cm−2, respectively. Finally, a new electrode was fabricated using disposable materials, specifically from the graphite rod of a dry cell. We evaluated how effectively the AuNPs-modified Gr electrode sensor could detect traces of CIP in ultra-pure water samples. The experiment yielded a limit of detection (LOD) of 0.0517 nM and a limit of quantification (LOQ) of 1.723 nM. The findings indicate that this newly developed electrode can quickly and accurately identify ciprofloxacin in water samples, making it valuable for rapid and sensitive analysis.
Description: A Master of Science (M.Sc.) Thesis in Chemistry Department at Chittagong University of Engineering and Technology (CUET).
URI: http://103.99.128.19:8080/xmlui/handle/123456789/626
Appears in Collections:Thesis in Chemistry

Files in This Item:
File Description SizeFormat 
23.09.2025_Tmail-18_Tahmina Akter_21MSCHEM002F.pdfA Master of Science (M.Sc.) Thesis in Chemistry Department at Chittagong University of Engineering and Technology (CUET).8.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.